ASTM E384 10E2 PDF

0 Comments

Status: Alert Withdrawn. Norwegian title: Standard Test Method for Knoop and Vickers Hardness of Materials. English title: Standard Test Method for Knoop and . ASTM Ee2. Historical Standard: ASTM Ee2 Standard Test Method for Knoop and Vickers Hardness of Materials. SUPERSEDED (see Active link. ASTM Ee2. February Standard Test Method for Knoop and Vickers Hardness of Materials. Historical Version.

Author: Fejas Vudogal
Country: Vietnam
Language: English (Spanish)
Genre: Automotive
Published (Last): 28 October 2018
Pages: 96
PDF File Size: 5.98 Mb
ePub File Size: 11.81 Mb
ISBN: 941-9-28522-156-6
Downloads: 91736
Price: Free* [*Free Regsitration Required]
Uploader: Zolor

On examination, accident investigators found that the sub-standard pins had a hardness value of only some 01e2. No further reproductions authorized.

Register for a trial account.

Ee2 Standard Test Method for Knoop and Vickers Hardness of Materials, –

This is not a good indentation. A web subscription provides an easy and secure access to standards, and you are guaranteed to always have the latest edition. NOTE 2—While Committee E04 e348 primarily concerned with metals, the test procedures described are applicable to other materials.

Meyer hardness test Rockwell scale Vickers toughness test of ceramics. The moment new editions of the standards you monitor are released, changes are made, or appendixes are published, you will be alerted by email.

The hardness number is determined by the load over the surface area of the indentation and not the area atm to the force, and is therefore not pressure. Please sign into an account with a subscription to this content, or email for help at support madcad. This ensures that you are always up-to-date and saves you both time and money.

You need to log in before adding standards to the monitoring service. Webprint Printed and bound.

Vickers hardness test

Content only available by subscription. I,p — Originally approved in The electronic file may not be reproduced in any way. Some manufactures are promoting that they have watch glass at Vickers compared to other watches rating at This service is not available if you are a URL user where you do not log in with an email awtm.

  DEI 520T PDF

The fin attachment pins and sleeves in the Convair airliner were specified by the aircraft manufacturer to be hardened to a Vickers Hardness specification of HV5, the ‘5’ meaning five kiloponds. Remember me for one month. To calculate Vickers hardness number using SI units one needs to convert the force 10r2 from newtons to kilogram-force by dividing by 9. For thin samples indentation depth can be an issue due to substrate effects.

Search book title Enter keywords for book title search. Smith and George E. Last previous edition approved in as E — 10e2.

Start Webshop Product catalog Product presentation. The right to access the electronic files of ASTM Standards is for purposes of viewing for individual use only. The difference in length of both diagonals and astn illumination gradient, are both classic indications of an out-of-level sample. The last approved version of this historical standard is referenced.

Standards monitoring is a free service designed for you who wish to be alerted of changes to or new editions of the standards required in your work. Read more about subscriptions. Alternatively indent depth can be calculated according to:. In addition the electronic files may not be downloaded or distributed elsewhere over computer networks or otherwise. This standard has been approved for use by agencies of the Department of Defense.

However, because of the historical precedent and continued common usage, force values in gf and kgf units are provided for information and much of the discussion in this standard as well as the method of reporting the test results refers to these units. A number in parentheses indicates the year of last reapproval. If you need to be able to add standards to the monitoring service, you must register as a user asttm your own username and password.

  BHIKKHU BODHI NOBLE EIGHTFOLD PATH PDF

Enter your account email address to request a password reset: There were no books found for the applied search filters.

A diamond in the form of a square-based pyramid satisfied these conditions. While they are progressively making their watches better, they are aatm using it as a marketing information for the consumer. The hardness number can be converted into units of pascalsbut should not be confused with pressure, which also has units of pascals. ASTM grants you a license as follows: The last approved version of this historical standard is referenced on www. The pyramidal diamond indenter of a Vickers hardness tester.

Currently some watch companies are improving the crystal watch glass by testing the strength using the Vickers hardness test. Vickers hardness test A Vickers atm tester. NOK 1 ,00 excl. Vickers values are generally independent of the test force: An indentation left in case-hardened steel after a Vickers hardness test.

ASTM E384:10e2

Are you r384 you want to empty the cart? A can be determined by the formula. Subscription – always available and updated A web subscription provides an easy and secure access to standards, and you are guaranteed to always have the latest 3e84. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Print 1 2 3 4 5 page sstarting from page current page.

When doing the hardness tests the minimum distance between indentations and the distance from the indentation to the edge of the specimen must be taken into account to avoid interaction between the work-hardened regions and effects of the edge.